Home arrow Hardware arrow ipEther232.IO

Data Logger / Event Logger with Digital I/O (Input/Output)

Digital I/O (Input/Output)- Data Logger / Event Logger

ipEther232.IO is a Data Logger / Event Logger with digital I/O's (Input/Output) enabling the acquisition of digital values, e.g. process and machine data. This data can then be sent automatically to a workstation via Ethernet for further processing. The data/event logger is also capable of controlling other devices via digital outputs.
The e
xtensive software included in the delivery and its exceptional versatility make this product an excellent choice with a profitable price-performance ratio.






The data logger / event logger records, counts,
monitors, analyzes and visualizes
digital signals and sends alerts.
acquisiton of digital signals for further individual processing over the Ethernet
digital IO bit patterns acquire The event- data logger ipEther232.IO
Records:
- events
- bit patterns
- counter
   values
    ipEther232.IO   Conventional
PC or server


The data/event logger has six individual channels (either 6x digital inputs or 4x digital inputs and 2x digital output ´s) and one RS232 serial interface for digital data acquisiton. The 24V digital input channels comply with the general industrial standard for automation and process controlling, and an optocoupler provides DC isolation. Relay contacts are standardly used on the digital output channels for DC isolation.

For additional convenience, the serial RS232 interface also enables easy data acquisition via log printer interface  (Optionally, a parallel interface can be connected). The RS232 interface can also be used to connect additional devices with Rx/Tx via SUB D9 connectors, eg. LCDs, or bar code scanners.

The data/event logger can cache digital I/O (Input/Output) events and RS232 data, should the server/PC connection via Ethernet fail. As soon as the Ethernet connection is restored, the data/event logger transmits the buffered digital I/O (Input/Output) and RS232 data to the server or PC again.

The data/event logger features compact design, easy integration, and a wide range of applications. These include the acquisition of process and machine data, automation, building control systems, and measurement data acquisition.

Since the data/event logger is installed directly at the machines, systems or test stands, it enables cost-saving installation with short wire connections to the digital channels or RS232 interfaces. ipEther232.IO is also suitable for very large plants since any number of ipEther232.IO digital IOs (digital Input/ digital Output) can be integrated into your company network via Ethernet.

The ipEther232.IO data/event logger can be integrated easily into existing PC networks via Ethernet interface. Standard PCs and tools, such as Excel, Access, SQL, or OPC can be used for further processing of transmitted data.

There is a wide range of software available on the market. Whatever you wish to accomplish - from simple visualization tasks to complex monitoring systems such as FAMOUS - ipEther232.IO provides you with all the options you need for monitoring and process analysis.



Application range of the included software

To ensure that the software can be adapted exactly to your individual requirements, the complete source code is included in the delivery.

datalogger consoleData Logger / Event Logger - Console
This console application displays the signal changes at the various digital input lines of the data/event logger.
Database DataloggerData Logger - Database
Data transmitted by the data logger and tagged with a time stamp can be entered into this database via Ethernet.
DataLogger - MS ExcelData Logger - MS Excel
Data transmitted by the data logger can be evaluated in Excel and then visualized.
I/O BoxData Logger - IO (Input/Output) Box Control
The data logger can be controlled very easily using well-established programs such as Office, VisualBasic or .Net applications.
OPC Event LoggerData-Event-Logger - OPC
The OPC software provides the connecting link between the data/event logger and the visualization software.
Data IO WindowsData Event Logger - Windows
The Windows.Forms application provides a clear and detailed overview of all the operations in the data/event logger.
OCX - HTML dataData Event Logger with OCX and HTML
OCX software is used to actively control the data/event logger. The log data are displayed in an html document.
IO Box ReaderData Logger - IO Box Reader
A C# class library facilitates the setting of parameters for the data/event logger. The included sample programs are also based on this library.

... Advantages... Specifications ... Applications
  • Secure UDP transfer
  • Cyclic or event-triggered
  • Up to 4 clients (PC connections) simultaneously
  • Documented transmission of plain text format (open interface)
  • Simple modular integration
  • "Local" and "remote" configuration
  • Password protection against unauthorized access
  • Easy installation and configuration
    enable use in complex networks
  • Diagnostic log files and LEDs for
    I/O (Input/Output), Ethernet and RS232
  • 6x 24 V DC input channels or
    4x 24 V DC input and
    2x relay output channels
  • Reverse voltage protection
  • 1,5 KV isolation voltage
  • Can buffer 50 digital changes
  • RS232 transparent read/write
  • Can buffer approximately 32 KByte RS232 data
  • MAC based IP configuration
  • 6x 32 bit counter values
  • Acquisition of bit patterns,
    counter values, events
  • Input cycle 1 to 255 ms
  • Input debouncing off / or 1- to 15-fold scan cycle


  • Optional:
      - DIN-Rail unit
        with 24/48/60 V DC
        power supply
      - Bar code reader
      - Line display
    Open Interface:
  • Windows.Forms Control
  • OCX / ActiveX Control
  • OPC DA 2.0 / 3.0

  • Sample programs:
  • Source code in Microsoft .NET
  • MSDN-compatible help files
  • Sample with Microsoft Excel
  • Database application
    (Events stored in Access/SQL server or Oracle)
  • Example with Windows interface
  • Console program
  • Viewing events on HTML page



Specifications of the Data Logger ipEther232.IO

ipEther232.IOOEM VersionDesktopDIN-Rail Unit
Interfaces ipEther232.IO • 1x RS232 SUB-D9 (RX / TX / GND)
• 6x 24V DC input channels or
4x 24V DC input and 2x relay output channels 24V/1A
• Isolation voltage: 1,5 KV
• Channel separation: 500 V (galvanically isolated in three groups)
• Input scan cycle: 1 to 255 ms
• Input debouncing: 1- to 15-fold scan cycle
1 x 10BaseT - RJ45 (for networks at 10/100 MBit/s)
Diagnostics LEDs Power, System, Error
RS232 Send/Receive
Ethernet Send/Receive/Link
Power Supply
+ 8-14 V DC - input jack
5 V DC male header on board
+ 8-14 V DC - input jack + 8-14 or 24 V DC1)
input jack and
3.5mm connector
Casing Without case Plastic case Plastic case
Measurements W/H/D Approx. 100/20/70 mm Approx. 110/30/75 mm Approx. 45/108/73 mm
Operating/Storage temperature 5° C to 55° C / -10° C to 70° C
Relative humidity 5 % to 90 %, non-condensing
Standards CE
Scope of supply Data logger - ipEther232.IO
Without power pack Power supply 2)
Input: 230 V AC
Output: + 9 V DC
Without power pack
(Optional)
Configuration software,
Driver for Windows (NT, 2000, XP),
Documentation on CD (German or English)
Purchase order number 6x Input
1x RS232
0202023-OEM 0202023 0202023-H
0202023-H24
0202023-H60
4x Input
2x Output
1x RS232
0202024-OEM 0202024 0202024-H
0202024-H24
0202024-H60
--> Shop

1)Further voltages for the data logger on request
2) Delivery to countries with 230 V AC 50Hz only.
Subject to change without prior notice
<<
↑