Data Logger / Event Logger with Digital I/O (Input/Output)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||
|
The data/event logger has six individual channels (either 6x digital inputs or 4x digital inputs and 2x digital output ´s) and one RS232 serial interface for digital data acquisiton. The 24V digital input channels comply with the general industrial standard for automation and process controlling, and an optocoupler provides DC isolation. Relay contacts are standardly used on the digital output channels for DC isolation.
For additional convenience, the serial RS232 interface also enables easy data acquisition via log printer interface (Optionally, a parallel interface can be connected). The RS232 interface can also be used to connect additional devices with Rx/Tx via SUB D9 connectors, eg. LCDs, or bar code scanners.
The data/event logger can cache digital I/O (Input/Output) events and RS232 data, should the server/PC connection via Ethernet fail. As soon as the Ethernet connection is restored, the data/event logger transmits the buffered digital I/O (Input/Output) and RS232 data to the server or PC again.
The data/event logger features compact design, easy integration, and a wide range of applications. These include the acquisition of process and machine data, automation, building control systems, and measurement data acquisition.
Since the data/event logger is installed directly at the machines, systems or test stands, it enables cost-saving installation with short wire connections to the digital channels or RS232 interfaces. ipEther232.IO is also suitable for very large plants since any number of ipEther232.IO digital IOs (digital Input/ digital Output) can be integrated into your company network via Ethernet.
The ipEther232.IO data/event logger can be integrated easily into existing PC networks via Ethernet interface. Standard PCs and tools, such as Excel, Access, SQL, or OPC can be used for further processing of transmitted data.
There is a wide range of software available on the market. Whatever you wish to accomplish - from simple visualization tasks to complex monitoring systems such as FAMOUS - ipEther232.IO provides you with all the options you need for monitoring and process analysis.
|
Application range of the included software
| To ensure that the software can be adapted exactly to your individual requirements, the complete source code is included in the delivery. |
Data Logger / Event Logger - ConsoleThis console application displays the signal changes at the various digital input lines of the data/event logger. |
Data Logger - DatabaseData transmitted by the data logger and tagged with a time stamp can be entered into this database via Ethernet. |
Data Logger - MS ExcelData transmitted by the data logger can be evaluated in Excel and then visualized. |
Data Logger - IO (Input/Output) Box ControlThe data logger can be controlled very easily using well-established programs such as Office, VisualBasic or .Net applications. |
Data-Event-Logger - OPCThe OPC software provides the connecting link between the data/event logger and the visualization software. |
Data Event Logger - WindowsThe Windows.Forms application provides a clear and detailed overview of all the operations in the data/event logger. |
Data Event Logger with OCX and HTMLOCX software is used to actively control the data/event logger. The log data are displayed in an html document. |
Data Logger - IO Box ReaderA C# class library facilitates the setting of parameters for the data/event logger. The included sample programs are also based on this library. |
| ... Advantages | ... Specifications | ... Applications |
|---|---|---|
|
|
Sample programs: |
Specifications of the Data Logger ipEther232.IO
| ipEther232.IO | OEM Version | Desktop | DIN-Rail Unit | |
|---|---|---|---|---|
| Interfaces ipEther232.IO | • 1x RS232 SUB-D9 (RX / TX / GND) • 6x 24V DC input channels or 4x 24V DC input and 2x relay output channels 24V/1A • Isolation voltage: 1,5 KV • Channel separation: 500 V (galvanically isolated in three groups) • Input scan cycle: 1 to 255 ms • Input debouncing: 1- to 15-fold scan cycle |
|||
| 1 x 10BaseT - RJ45 (for networks at 10/100 MBit/s) | ||||
| Diagnostics LEDs | Power, System, Error RS232 Send/Receive Ethernet Send/Receive/Link |
|||
| Power Supply |
+ 8-14 V DC - input jack 5 V DC male header on board |
+ 8-14 V DC - input jack | + 8-14 or 24 V DC1) input jack and 3.5mm connector |
|
| Casing | Without case | Plastic case | Plastic case | |
| Measurements W/H/D | Approx. 100/20/70 mm | Approx. 110/30/75 mm | Approx. 45/108/73 mm | |
| Operating/Storage temperature | 5° C to 55° C / -10° C to 70° C | |||
| Relative humidity | 5 % to 90 %, non-condensing | |||
| Standards | CE | |||
| Scope of supply | Data logger - ipEther232.IO | |||
| Without power pack | Power supply 2) Input: 230 V AC Output: + 9 V DC |
Without power pack (Optional) |
||
| Configuration software, Driver for Windows (NT, 2000, XP), Documentation on CD (German or English) |
||||
| Purchase order number | 6x Input 1x RS232 |
0202023-OEM | 0202023 | 0202023-H 0202023-H24 0202023-H60 |
| 4x Input 2x Output 1x RS232 |
0202024-OEM | 0202024 | 0202024-H 0202024-H24 0202024-H60 |
|
1)Further voltages for the data logger on request 2) Delivery to countries with 230 V AC 50Hz only. Subject to change without prior notice |
||||








Data Logger / Event Logger - Console
Data Logger - Database
Data Logger - MS Excel
Data Logger - IO (Input/Output) Box Control
Data-Event-Logger - OPC
Data Event Logger - Windows
Data Event Logger with OCX and HTML
Data Logger - IO Box Reader